Place of Origin : China
Brand Name : ARI
Model Number : AR-324
Main body  | High-strength engineering plastic rack, light, beautiful and corrosion resistant  | 
Scope of application  | adult, child  | 
Gas source  | O2: 0.27--0.55MPa N2O: 0.27--0.55MPa  | 
Flow meter  | O2: 0.1--1.0L/min 1.1--10L/min N20: 0.1--1.0L/min 1.1--10L/min  | 
O2, N2O linkage and N2O Stopper  | When using nitrous oxide, oxygen concentration>25%; When the oxygen pressure<0.2Kpa, the flow of nitrous oxide would be cut off  | 
Flow rate of rapid oxygen supply  | 25--75L/min  | 
Low oxygen pressure alarm  | There will be sound alarm when the oxygen pressure < 0.2MPa  | 
Vaporizer  | it has the function of automatic compensation based onpressure, temperature, and flow rate. The regulation range of evaporator concentration is 0--5 vol%. Among Halothane,Enflurane,Isoflurane and Sevoflurane,two can be chosen for application as required by the customer. And vaporizers that are imported with original packaging are also available.  | 
Respiratory circuit  | working mode: all-close, semi-close, semi-open APL: 0.5--7 kPa  | 
Respiratory Bellows  | bellows for adults, bellows for children tidal volume range:0--1,500 ml  | 
Ventilator  | |
Display mode  | High-definition 5.7” LCD screen display  | 
Ventilation mode  | IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH  | 
Ventilation parameters  | Tidal volume 50--1500 ml Rate 2--99 bpm SIMV rate 2--20 bpm I:E 2:1--1:8 Inspiratory trigger pressure -1.0--2.0 kPa PEEP 0--2.0 kPa Pressure range 1.0--6.0 kPa SIGH 1.5 times the inspiratory time  | 
Parameters for ventilation monitoring  | tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure  | 
Monitoring of oxygen concentration  | (21%--100%)  | 
Security Alarm System  | |
Oxygen Concentration alarm  | upper limit setting range (50%--100%) low limit setting range (15%--50%)  | 
Airway pressure alarm  | upper limit setting range 1.0--6.0 kPa low limit setting range 0.4--2.0 kPa  | 
Per-minute ventilation volume alarm  | upper limit setting range 3.0--30L/min low limit setting range 1.0--10L/min  | 
Sustained high-pressure alarm  | it will give alarm when stress have consistently been higher than 2.5 kPa  | 
Suffocation alarm  | it will give sound and light alarm if there is no tidal volume input for 15 seconds  | 
Power alarm  | |
Power  | AC 220V±10% 50Hz±1Hz (UPS, Storage battery)  | 
(Mechanical Arms)  | |
(End-expiratory CO2 monitoring)  | |
*Items within brackets are optional.  | |
| 
                                             | 
                